考虑离散调压设备动作频次的高压直流输电系统控制优化
作者:
作者单位:

1.国网经济技术研究院有限公司,北京市 102209;2.国家电网有限公司,北京市 100031;3.国网青海省电力公司,青海省 西宁市 810000

摘要:

目前中国在运行直流工程普遍采用传统控制模式,当直流功率和电压波动时可能引起直流离散调压设备的频繁动作,直接影响了直流工程的运行可靠性。针对降低直流系统离散调压设备动作频次的技术需求,首先分析了高压直流输电系统离散调压设备动作的影响因素;基于此,考虑分接开关、交流滤波器和动态无功补偿的协调,分别对直流传统定熄弧角和定直流电压控制模式进行了改进,提出了直流运行电压在选定功率区间内随直流功率变化;然后分析了所提策略的影响,并给出了相应优化建议;最后基于直流主回路计算和电磁暂态仿真,对上述分析进行验证。结果表明,所提策略能够有效降低直流系统离散调压设备的动作频次。

关键词:

基金项目:

国家电网公司科技项目(5102-201956301A-0-0-00)。

通信作者:

作者简介:

索之闻(1988—),男,通信作者,博士,工程师,主要研究方向:高压直流输电系统设计、交直流混合电力系统安全稳定分析。E-mail:suozhiwen@126.com
李晖(1981—),男,博士,教授级高级工程师,主要研究方向:智能电网规划。
蒋维勇(1979—),男,博士,教授级高级工程师,主要研究方向:高压直流输电系统设计、交直流混合电力系统安全稳定分析。


Control Optimization of HVDC System Considering Action Frequency of Discrete Voltage Regulation Equipment
Author:
Affiliation:

1.State Grid Economic and Technological Research Institute Co., Ltd., Beijing 102209, China;2.State Grid Corporation of China, Beijing 100031, China;3.State Grid Qinghai Electric Power Company, Xining 810000, China

Abstract:

At present, the traditional control mode is commonly used in China’s running HVDC projects, which may lead to frequent action of DC discrete voltage regulation equipment with a fluctuation of DC power and voltage, and directly affect the HVDC project operation reliability. In view of the technical requirement for reducing the action frequency of DC discrete voltage regulating equipment, this paper firstly analyzes the action influencing factors of discrete voltage regulation equipment. Based on this, the HVDC traditional constant extinction angle and constant DC voltage control modes are respectively improved considering the coordination of tap-changer, AC filter and dynamic reactive compensation. And DC operating voltage varies with DC power within selected power range is proposed. Then the impact of the proposed strategy is analyzed and the corresponding optimization suggestions are given. Finally, the above analysis is verified based on DC main loop calculation and electromagnetic transient simulation. The results show that the proposed strategy can effectively reduce the action frequency of DC discrete voltage regulating equipment.

Keywords:

Foundation:
This work is supported by State Grid Corporation of China (No. 5102-201956301A-0-0-00).
引用本文
[1]索之闻,李晖,蒋维勇,等.考虑离散调压设备动作频次的高压直流输电系统控制优化[J].电力系统自动化,2020,44(3):211-219. DOI:10.7500/AEPS20190823003.
SUO Zhiwen, LI Hui, JIANG Weiyong, et al. Control Optimization of HVDC System Considering Action Frequency of Discrete Voltage Regulation Equipment[J]. Automation of Electric Power Systems, 2020, 44(3):211-219. DOI:10.7500/AEPS20190823003.
复制
支撑数据及附录
分享
历史
  • 收稿日期:2019-08-23
  • 最后修改日期:2019-10-16
  • 录用日期:
  • 在线发布日期: 2020-02-14
  • 出版日期: